SCA65F-EJ2A
Two-foot (0.5 m), dual-band, eight-port panel, 65° azimuth beamwidth, 1695–2690 and 5150–5925 MHz.
- Peak gain
- 13.3 dBi
- Ports
- 8
- Size
- 509 x 302 x 123 mm
CCI
One-foot (0.3 m), dual-band, eight-port panel, 65° azimuth beamwidth and 40° elevation beamwidth, covering 1695–2690 and 5150–5925 MHz.
Display units
Converted for display only. Wind speed, beamwidth, tilt, PIM, VSWR and impedance are shown as published.
Addition: not in the sheet and not in the library; found in CCI's product archive while resolving the batch-4 missing models. End-of-life September 24, 2024 (EOL-240924-03); no replacement named. Front-to-back ratio published as a minimum ('> N dB') in the datasheet; recorded as the plain number. Ordering part SCA65F-EJ1AA-K.
| Band, MHz | Ports | Gain | Horizontal BW | Vertical BW | Electrical tilt | PIM, dBc | Power / port |
|---|---|---|---|---|---|---|---|
| 1695–1880MHz | 1-4 | 10.7dBiavg 9.8 | 70° | 47° | 4° fixed | -153dBc | 100W |
| 1850–1990MHz | 1-4 | 10.7dBiavg 10.2 | 68° | 45° | 4° fixed | -153dBc | 100W |
| 1920–2180MHz | 1-4 | 10.9dBiavg 10.4 | 66° | 44° | 4° fixed | -153dBc | 100W |
| 2300–2400MHz | 1-4 | 11dBiavg 10.6 | 68° | 38° | 4° fixed | -153dBc | 100W |
| 2496–2690MHz | 1-4 | 11.2dBiavg 10.8 | 71° | 34° | 4° fixed | -153dBc | 100W |
| 5150–5925MHz | 5-8 | 5.8dBiavg 5.2 | 72° | 26° | 5° fixed | Not published | 10W |
Fixed 4° downtilt in 1695–1880 MHz
Fixed 4° downtilt in 1850–1990 MHz
Fixed 4° downtilt in 1920–2180 MHz
Fixed 4° downtilt in 2300–2400 MHz
Fixed 4° downtilt in 2496–2690 MHz
Fixed 5° downtilt in 5150–5925 MHz
Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.
Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.
EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →
Specifications belong to CCI and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.