CommScope

3X-NV4SS-65S-F2

42-port trisector small-cell canister, 6x 698–896 + 24x 1695–2690 + 12x 3300–4000, 65° HPBW, fixed tilt.

Antenna · Multi-Beam Multi-Beam Small cell Verified from manufacturer datasheet
Manufacturer PDF Product page

Public datasheet summary. The specifications on this page are taken from CommScope’s publicly available datasheet, linked above. CommScope owns its name, trademarks and specifications, which may change without notice. This site is not affiliated with, endorsed by, or sponsored by CommScope, and nothing here is proprietary to this site. Values are provided as-is for reference only — the manufacturer’s current datasheet is the authoritative source.

Own family, not a variant of the NNV4SS/NNV4S panel family: a 42-port trisector small-cell canister (three 120° sectors in one 370 mm diameter housing), vs the NNV4S flat panels already in the library. Dimensions are length 610 mm x outer diameter 370 mm. Fixed tilt per band (6° low, 4° mid, 2° C-band). The datasheet publishes no USLS row, so usls_db is null on all bands; gain_dbi is the peak Gain row (a Gain at Mid Tilt row is also printed: 10.3/10.6/10.8/11.4/13.6 dBi). Total input power 2,320 W carries no temperature qualifier in the PDF. Sector azimuths are read from the datasheet's Port Configuration diagram (Sector 1 = 0° reference; sectors 120° apart) - no absolute azimuth is published. Small-cell: andrew.com lists the product type as 'Small cell antenna' (the PDF's Antenna Type is 'Tri-sector'). Mounting kits MC-MNT-SIDE-370 and MC-MNT-TOP-370 are listed as related products, ordered separately. Revision July 14, 2026, recorded as printed.

SPEC.COVCoverage5 band rows
Band, MHz Ports GainHorizontal BWVertical BWElectrical tilt PIM, dBc Power / port
698–896MHz 1-6 10.5dBi 76° 37.8° 6° fixed -153dBc 100W
1695–1920MHz 7-30 11.3dBi 66° 36.5° 4° fixed -153dBc 100W
1920–2200MHz 7-30 11.4dBi 71° 31.6° 4° fixed -153dBc 100W
2300–2690MHz 7-30 12dBi 70° 26.6° 4° fixed -153dBc 100W
3300–4000MHz 31-42 14.1dBi 58° 15.7° 2° fixed -145dBc 75W
SPEC.BEMBeams3 beams

One antenna, many beams. Each beam is an independent narrow sector with its own ports, so a single antenna can cover several directions at once — useful on stadiums, venues and dense sites, where it replaces several separate antennas.

All beams cover 698–4000MHz.

Beam Azimuth Ports Note
Sector 1 0° 1-2, 7-14, 31-34 Sector 1 of the trisector; 14 ports (2 low, 8 mid, 4 C-band). Azimuth read from the datasheet's Port Configuration diagram (Sector 1 = 0° reference; sectors 120° apart) - no absolute azimuth is published. Per-band specs (gain, beamwidths, fixed tilt 6° low / 4° mid / 2° C-band) are in bands[].
Sector 2 240° 3-4, 15-22, 35-38 Sector 2 of the trisector; 14 ports (2 low, 8 mid, 4 C-band). Azimuth read from the datasheet's Port Configuration diagram (Sector 1 = 0° reference; sectors 120° apart) - no absolute azimuth is published. Per-band specs are in bands[].
Sector 3 120° 5-6, 23-30, 39-42 Sector 3 of the trisector; 14 ports (2 low, 8 mid, 4 C-band). Azimuth read from the datasheet's Port Configuration diagram (Sector 1 = 0° reference; sectors 120° apart) - no absolute azimuth is published. Per-band specs are in bands[].
SPEC.ELEElectrical
Polarization
±45°
VSWR
1.5: 1
PIM, 3rd order
By band, see Coverage
Max input power
2320W total2,320 W total (no temperature qualifier published). Per-port figures are the datasheet's ratings at 50 °C.
Impedance
50Ω
Isolation
25 cross-polar, 25 inter-band
SPEC.MECMechanical
Dimensions
610 x 370 (diameter)mm
Weight
15.6kgwithout mounting kit
Wind load
129.0 N at 150 km/h
Max wind speed
241 km/h (150 mph)
Connectors
42x 4.3-10 female, bottom
Port count
42
Mounting
Not published
SPEC.PRTPorts42 total
  • Ports 1-6 698–896MHz
  • Ports 7-30 1695–2690MHz
  • Ports 31-42 3300–4000MHz
1+2−3+4−5+6−7+8−9+10−11+12−13+14−15+16−17+18−19+20−21+22−23+24−25+26−27+28−29+30−31+32−33+34−35+36−37+38−39+40−41+42−
Illustrative port layout — drawn from the published 42 ports and ±45° polarization. The arrangement is schematic; the exact positions are in the manufacturer PDF.
  • Ports 1–6698–896MHz
  • Ports 7–301695–2690MHz
  • Ports 31–423300–4000MHz
SPEC.PATRadiation patterns5 bands
0°90°180°270°All beams · 3 azimuths
All beams — horizontal · 3 distinct azimuths · lobe widths from the 1930 MHz band (HBW 71°) — per-beam widths are published per sub-band, not per beam
0°90°180°270°HBW 76°
Horizontal — 698–896MHz
0°90°180°270°VBW 37.8°tilt 6°
Vertical — 698–896MHz

Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.

CALC.EIRPUse this gainEIRP / ERP

Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.

EIRP — Turn on JavaScript, or use the calculator link.

EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →

SOURCESource and corrections
Source
Manufacturer datasheet PDF, read 2026-11-20: https://es.andrew.com/globalassets/digizuite/1020511-p360-3x-nv4ss-65s-f2-external.pdf
Datasheet revision
Revised July 14, 2026
Added

Specifications belong to CommScope and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary. This site is not affiliated with, endorsed by, or sponsored by CommScope. If you represent CommScope and want a correction or removal, use “Report an error” below.

Report an error in these specs