NNV4SSP-360S-F2
18-port small-cell canister, 360° pattern, fixed tilt.
- Peak gain
- 9 dBi
- Ports
- 18
- Size
- 610 x Ø370 mm
CommScope
10-port small-cell canister, 360° pattern, fixed tilt.
Display units
Converted for display only. Wind speed, beamwidth, tilt, PIM, VSWR and impedance are shown as published.
| Band, MHz | Ports | Gain | Horizontal BW | Vertical BW | Electrical tilt | PIM, dBc | Power / port |
|---|---|---|---|---|---|---|---|
| 1695–1920MHz | 1-4 | 6.6dBi | 360° | 21.9° | 7° fixed | -153dBc | 125W |
| 1920–2180MHz | 1-4 | 7.3dBi | 360° | 19.1° | 7° fixed | -153dBc | 125W |
| 2300–2690MHz | 1-4 | 8.2dBi | 360° | 15.6° | 7° fixed | -150dBc | 125W |
| 3300–3550MHz | 5-8 | 5.6dBi | 360° | 38.8° | 0° fixed | -145dBc | 35W |
| 3550–3700MHz | 5-8 | 5.9dBi | 360° | 36.8° | 0° fixed | -145dBc | 35W |
| 3700–4000MHz | 5-8 | 6dBi | 360° | 34.1° | 0° fixed | -145dBc | 35W |
| 5150–5925MHz | 9-10 | 5.1dBi | 360° | 22.4° | 0° fixed | Not published | 5W |
Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.
Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.
EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →
Specifications belong to CommScope and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.