Gamma Nu

QOY9X360F12T6

12-port pseudo-omni small-cell canister with a mid-band diplexer and 6° fixed tilt.

Antenna · Omni Small cell Verified from manufacturer datasheet
Manufacturer PDF Product page
SPEC.COVCoverage5 band rows
Band, MHz Ports GainHorizontal BWVertical BWElectrical tilt PIM, dBc Power / port
1850–1990MHz 1-4 8.8dBi maxavg 8.5 360° 15.9° 6° fixed -153dBc 100W
1695–1780MHz 5-8 8.9dBi maxavg 8.5 360° 16.8° 6° fixed -153dBc 100W
2110–2180MHz 5-8 9.2dBi maxavg 8.5 360° 13.2° 6° fixed -153dBc 100W
2300–2360MHz 5-8 9.2dBi maxavg 8.6 360° 12° 6° fixed -153dBc 100W
3300–4200MHz 9-12 9.1dBi maxavg 8.2 360° 15.1° Not published Not published 100W
SPEC.ELEElectrical
Polarization
±45°
VSWR
1.5: 1
PIM, 3rd order
By band, see Coverage
Max input power
100W per port
Impedance
50Ω
Isolation
>20 in-band cross-polar, >25 inter-band
SPEC.MECMechanical
Dimensions
600 x Ø240mm
Weight
8kgwithout mounting kit
Wind load
230 N at 100 mph
Max wind speed
150 mph (survival)
Connectors
12x 4.3-10 female, bottom
Port count
12
Mounting
Not published
SPEC.PRTPorts12 total
  • Ports 1-4 1850–1990MHz
  • Ports 5-8 1695–2360MHz
  • Ports 9-12 3300–4200MHz
1+2−3+4−5+6−7+8−9+10−11+12−
Illustrative port layout — drawn from the published 12 ports and ±45° polarization. The arrangement is schematic; the exact positions are in the manufacturer PDF.
  • Ports 1–41850–1990MHz
  • Ports 5–81695–2360MHz
  • Ports 9–123300–4200MHz
SPEC.PATRadiation patterns5 bands
0°90°180°270°HBW 360°
Horizontal — 1850–1990MHz
0°90°180°270°VBW 15.9°tilt 6°
Vertical — 1850–1990MHz

Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.

CALC.EIRPUse this gainEIRP / ERP

Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.

EIRP — Turn on JavaScript, or use the calculator link.

EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →

SOURCESource and corrections
Source
Manufacturer datasheet PDF, read 2026-11-11
Datasheet revision
July 2024
Added

Specifications belong to Gamma Nu and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.

Report an error in these specs

Upload a newer datasheet revision