FCC vs Safety Code 6 exposure limits
Canada and the US use different exposure limits and different averaging times (6 minutes in Canada, 30 minutes for the FCC public limit). At most cellular frequencies Canada is stricter.
Power-density limits at any frequency under both regulators. ISED column uses the exact power-density reference levels of Health Canada Safety Code 6 (2015), Tables 5 and 6.
Explained in FCC vs ISED Canada: Cross-Border RF Safety in Practice →
| POPULATION | FCC OET-65 (USA) | ISED · Safety Code 6 (Canada) | Δ (Stricter) |
|---|---|---|---|
| General Public / Uncontrolled | — | — | — |
| Occupational / Controlled | — | — | — |
| Time-Averaging (GP / Occ) | 30 / 6 min | 6 / 6 min | — |
For a cross-border program, the time-averaging difference alone can flip a borderline site. Between 300 MHz and 6 GHz, Safety Code 6's public limit is 0.02619·f0.6834 W/m² (f in MHz), averaged over 6 minutes; the FCC's is f/1500 mW/cm² from 300 to 1500 MHz, then 1.0 mW/cm², averaged over 30 minutes. Always reference the source regulatory text for compliance work.
The formula
Safety Code 6, uncontrolled, 300–6000 MHz: 0.02619 · f0.6834 W/m² (f in MHz)
Controlled, 100–6000 MHz: 0.6455 · f0.5 W/m²
Worked example
At 850 MHz: Safety Code 6 public limit ≈ 2.63 W/m²; FCC public limit ≈ 5.67 W/m². At 1900 MHz: about 4.56 W/m² against the FCC's 10 W/m².
Explained in more depth: FCC vs ISED Canada: Cross-Border RF Safety in Practice
Related calculators
Runs entirely in your browser; nothing you type is sent anywhere. For compliance work, always check the regulator's own text.