RF Tools

FCC MPE limits by frequency

The FCC sets power-density limits that depend on frequency and on who is exposed: the general public (uncontrolled) or workers who know about the exposure (controlled).

CALC.12 FCC OET-65 MPE Limit Lookup GENERAL PUBLIC · OCCUPATIONAL

Maximum Permissible Exposure power-density limits per FCC OET-65, Table 1. Type any cellular frequency to see the limit for that band.

Explained in OET-65 in 60 Seconds: How the FCC MPE Limits Actually Work →

MHz
General Public (Uncontrolled) · 30 min avg — mW/cm²
Occupational (Controlled) · 6 min avg — mW/cm²
Range Applied —
FREQUENCY RANGEGENERAL PUBLICOCCUPATIONAL
3 – 30 MHz180/f² mW/cm²900/f² mW/cm²
30 – 300 MHz0.2 mW/cm²1.0 mW/cm²
300 – 1500 MHzf / 1500 mW/cm²f / 300 mW/cm²
1.5 – 100 GHz1.0 mW/cm²5.0 mW/cm²

Source: FCC OET Bulletin 65, Edition 97-01, Table 1 (limits for Maximum Permissible Exposure). Below 3 MHz the limits are E-/H-field driven and not shown here.

The formula

General public: 0.2 mW/cm² (30–300 MHz), f/1500 (300–1500 MHz), 1.0 (1.5–100 GHz)
Occupational: 1.0 (30–300 MHz), f/300 (300–1500 MHz), 5.0 (1.5–100 GHz)

Worked example

At 850 MHz the general-public limit is 850 / 1500 ≈ 0.567 mW/cm² (5.67 W/m²); the occupational limit is about 2.83 mW/cm².

Explained in more depth: OET-65 in 60 Seconds: How the FCC MPE Limits Actually Work

Related calculators

Runs entirely in your browser; nothing you type is sent anywhere. For compliance work, always check the regulator's own text.