FCC MPE limits by frequency
The FCC sets power-density limits that depend on frequency and on who is exposed: the general public (uncontrolled) or workers who know about the exposure (controlled).
Maximum Permissible Exposure power-density limits per FCC OET-65, Table 1. Type any cellular frequency to see the limit for that band.
Explained in OET-65 in 60 Seconds: How the FCC MPE Limits Actually Work →
| FREQUENCY RANGE | GENERAL PUBLIC | OCCUPATIONAL |
|---|---|---|
| 3 – 30 MHz | 180/f² mW/cm² | 900/f² mW/cm² |
| 30 – 300 MHz | 0.2 mW/cm² | 1.0 mW/cm² |
| 300 – 1500 MHz | f / 1500 mW/cm² | f / 300 mW/cm² |
| 1.5 – 100 GHz | 1.0 mW/cm² | 5.0 mW/cm² |
Source: FCC OET Bulletin 65, Edition 97-01, Table 1 (limits for Maximum Permissible Exposure). Below 3 MHz the limits are E-/H-field driven and not shown here.
The formula
General public: 0.2 mW/cm² (30–300 MHz), f/1500 (300–1500 MHz), 1.0 (1.5–100 GHz)
Occupational: 1.0 (30–300 MHz), f/300 (300–1500 MHz), 5.0 (1.5–100 GHz)
Worked example
At 850 MHz the general-public limit is 850 / 1500 ≈ 0.567 mW/cm² (5.67 W/m²); the occupational limit is about 2.83 mW/cm².
Explained in more depth: OET-65 in 60 Seconds: How the FCC MPE Limits Actually Work
Related calculators
Runs entirely in your browser; nothing you type is sent anywhere. For compliance work, always check the regulator's own text.