CommScope

FFVV-65A-R2-V1

8-port 65° panel, 4x 617–894 + 4x 1695–2690, 2x RET.

Antenna · Panel Verified from manufacturer datasheet
Manufacturer PDF Product page
SPEC.COVCoverage8 band rows
Band, MHz Ports GainHorizontal BWVertical BWElectrical tilt PIM, dBc Power / port
617–698MHz 1,2,3,4 12.6dBi 66° 21.7° 5–22° -150dBc 250W
698–806MHz 1,2,3,4 13dBi 65° 19° 5–22° -153dBc 250W
806–894MHz 1,2,3,4 13.2dBi 58° 16.6° 5–18° -153dBc 250W
1695–1880MHz 5,6,7,8 16.3dBi 66° 7.7° 2–12° -153dBc 200W
1850–1990MHz 5,6,7,8 16.7dBi 67° 7.3° 2–12° -153dBc 200W
1920–2200MHz 5,6,7,8 17.4dBi 63° 6.7° 2–12° -153dBc 200W
2300–2500MHz 5,6,7,8 17.6dBi 57° 5.8° 2–12° -153dBc 200W
2500–2690MHz 5,6,7,8 18dBi 60° 5.7° 2–12° -153dBc 200W
SPEC.ELEElectrical
Polarization
±45°
VSWR
1.5: 1
PIM, 3rd order
By band, see Coverage
Max input power
900W total900 W total. Per-port figures are the datasheet's ratings.
Impedance
50Ω
Isolation
25 cross-polar, 25 inter-band
SPEC.MECMechanical
Dimensions
640 x 235 x 1224mm
Weight
33.2kgwithout mounting kit
Wind load
505.0 N at 150 km/h
Max wind speed
241 km/h (150 mph)
Connectors
8x 4.3-10 female, bottom
Port count
8
Mounting
BSAMNT-3
SPEC.PRTPorts8 total
  • Ports 1,2,3,4 617–894MHz
  • Ports 5,6,7,8 1695–2690MHz
1+2−3+4−5+6−7+8−
Illustrative port layout — drawn from the published 8 ports and ±45° polarization. The arrangement is schematic; the exact positions are in the manufacturer PDF.
  • Ports 1–4617–894MHz
  • Ports 5–81695–2690MHz
SPEC.PATRadiation patterns8 bands
0°90°180°270°HBW 66°
Horizontal — 617–698MHz
0°90°180°270°VBW 21.7°tilt 5–22°, shown at 13.5°
Vertical — 617–698MHz

Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.

CALC.EIRPUse this gainEIRP / ERP

Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.

EIRP — Turn on JavaScript, or use the calculator link.

EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →

SOURCESource and corrections
Source
Manufacturer datasheet PDF, read 2026-11-12: https://ja.andrew.com/globalassets/digizuite/635691-p360-ffvv-65a-r2-v1-external.pdf
Datasheet revision
Revised May 25, 2026
Added

Specifications belong to CommScope and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.

Report an error in these specs

Upload a newer datasheet revision