HEX338CU0000x
Tri Band, 6-Port, Panel, XPOL, 33°, 696-960 | 1695-2400 | 1695-2400 MHz, 2410 mm.
- Peak gain
- 18.8 dBi
- Ports
- 6
- Size
- 2410 x 724 x 153 mm
Amphenol
Tri Band, 6-Port, Panel, XPOL, 45°, 696-960 | 1695-2400 | 1695-2400 MHz, 1780 mm.
Display units
Converted for display only. Wind speed, beamwidth, tilt, PIM, VSWR and impedance are shown as published.
Parent code HEX456CU0000x (batch-7 rank 213): the x is the RET-actuator option in the datasheet ordering table (REV031020NA, p.7) - M manual tilt, G RET with MDCU, H RET with MDCU MULTI-RET ACTUATOR, L/L1/L2 RET with MDDU (different AISG port configurations). Datasheet recovered from the Wayback Machine snapshot (2022-01-16) of the manufacturer PDF at https://amphenol-antennas.com/datasheets/HEX456CU0000x.pdf; the live file was removed in the 2024 site redesign. This family has SIX variants, not five: the H variant (MDCU MULTI-RET ACTUATOR) appears in this REV031020NA ordering table and in no earlier HEX ordering table read so far. F/B printed as '>27 dB' (696-960) and '>28 dB' (1695-2400); USLS as '>17 dB' typical both bands; recorded as plain numbers. Gain is the single figure published per sub-band (no separate average). Isolation: in-band >25 dB both bands; between ports >30 dB. Ports assigned sequentially low to high (low 1-2, high arrays 3-6); the datasheet does not number the RF ports. Mounting bracket kit 36210008 ordered separately.
| Band, MHz | Ports | Gain | Horizontal BW | Vertical BW | Electrical tilt | PIM, dBc | Power / port | USLS, dB |
|---|---|---|---|---|---|---|---|---|
| 696–806MHz | 1-2 | 15.3dBi | 45° | 15.6° | 0–12° | -153dBc | 500W | 17dB |
| 806–960MHz | 1-2 | 16.2dBi | 40° | 13.7° | 0–12° | -153dBc | 500W | 17dB |
| 1695–1850MHz | 3-6 | 17.4dBi | 48° | 6.4° | 0–10° | -153dBc | 250W | 17dB |
| 1850–1990MHz | 3-6 | 18dBi | 45° | 6° | 0–10° | -153dBc | 250W | 17dB |
| 2100–2180MHz | 3-6 | 18.3dBi | 40° | 5.3° | 0–10° | -153dBc | 250W | 17dB |
| 2200–2400MHz | 3-6 | 18.3dBi | 40° | 5° | 0–10° | -153dBc | 250W | 17dB |
The trailing letter of the model code is the tilt-actuator option, from the datasheet ordering table (REV031020NA, p.7): M = Manual Electrical Tilt (MET); G = Remote Electrical Tilt (RET) with factory-installed MDCU (Multi-Device Control Unit); H = RET with factory-installed MDCU MULTI-RET ACTUATOR; L, L1 and L2 = RET with factory-installed MDDU (Multi-Device Dual Unit), differing in AISG port configuration. The RF specs are identical for all six variants.
| Variant code | What differs |
|---|---|
| HEX456CU0000M | Manual Electrical Tilt (MET), tilt knobs at the indicators, low band 0-12°, high bands 0-10° |
| HEX456CU0000G | Remote Electrical Tilt (RET) with factory-installed MDCU (Multi-Device Control Unit), AISG v2.0/3GPP |
| HEX456CU0000H | Remote Electrical Tilt (RET) with factory-installed MDCU MULTI-RET ACTUATOR, AISG v2.0/3GPP (second MDCU option in the REV031020NA ordering table; the table gives no further distinguishing spec) |
| HEX456CU0000L | RET with factory-installed MDDU (Multi-Device Dual Unit); AISG Port A Red (696-960 MHz), Port B Orange/Yellow (1695-2400 MHz) |
| HEX456CU000L1 | RET with factory-installed MDDU; AISG Port A Yellow (1695-2400 MHz), Port B Orange/Red (1695-2400 / 696-960 MHz) |
| HEX456CU000L2 | RET with factory-installed MDDU; AISG Port A Orange (1695-2400 MHz), Port B Yellow/Red (1695-2400 / 696-960 MHz) |
One antenna, one page — these are ordering options of this model, not separate models. The specs on this page apply to every variant unless the table says otherwise.
Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.
Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.
EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →
Specifications belong to Amphenol and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.