Band, MHz Ports GainHorizontal BWVertical BWElectrical tilt PIM, dBc Power / port
698–806MHz 1-2 12.5dBiavg 12.2 50° 33.2° 4° fixed -153dBc 500W
790–862MHz 1-2 12.7dBiavg 12.5 49° 31.1° 4° fixed -153dBc 500W
824–896MHz 1-2 13.2dBiavg 12.8 46° 30.4° 4° fixed -153dBc 500W
880–960MHz 1-2 13.4dBiavg 13.2 43° 29.1° 4° fixed -153dBc 500W
1695–1880MHz 3-6 14.4dBiavg 13.5 44° 19.4° 4° fixed -153dBc 300W
1850–1990MHz 3-6 14.7dBiavg 14.1 41° 18.4° 4° fixed -153dBc 300W
1920–2180MHz 3-6 15.1dBiavg 14.6 39° 17.4° 4° fixed -153dBc 300W
2300–2400MHz 3-6 15.8dBiavg 15.1 38° 15.1° 4° fixed -153dBc 300W
2496–2690MHz 3-6 15.9dBiavg 15.3 38° 14° 4° fixed -153dBc 300W

Fixed 4° downtilt in 698–806 MHz

Fixed 4° downtilt in 790–862 MHz

Fixed 4° downtilt in 824–896 MHz

Fixed 4° downtilt in 880–960 MHz

Fixed 4° downtilt in 1695–1880 MHz

Fixed 4° downtilt in 1850–1990 MHz

Fixed 4° downtilt in 1920–2180 MHz

Fixed 4° downtilt in 2300–2400 MHz

Fixed 4° downtilt in 2496–2690 MHz

SPEC.ELEElectrical
Polarization
±45°
VSWR
1.5: 1
PIM, 3rd order
By band, see Coverage
Max input power
By band, see Coverage
Impedance
50Ω
Isolation
>25 dB (698–960 MHz, 1695–2690 MHz)
SPEC.MECMechanical
Dimensions
618 x 391 x 208mm
Weight
6.9kgexcludes mounting
Wind load
Front 355 N, side 192 N at 100 mph
Max wind speed
241 km/h (150 mph)
Connectors
6x 4.3-10 female
Port count
6
Mounting
MBK-03 mounting bracket included
SPEC.PRTPorts6 total
  • Ports 1-2 698–960MHz
  • Ports 3-6 1695–2690MHz
1+2−3+4−5+6−
Illustrative port layout — drawn from the published 6 ports and ±45° polarization. The arrangement is schematic; the exact positions are in the manufacturer PDF.
  • Ports 1–2698–960MHz
  • Ports 3–61695–2690MHz
SPEC.PATRadiation patterns9 bands
0°90°180°270°HBW 50°
Horizontal — 698–806MHz
0°90°180°270°VBW 33.2°tilt 4°
Vertical — 698–806MHz

Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.

CALC.EIRPUse this gainEIRP / ERP

Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.

EIRP — Turn on JavaScript, or use the calculator link.

EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →

SOURCESource and corrections
Source
Manufacturer datasheet PDF, read 2026-11-12: https://cciproducts.com/DsPdf/ds-hpa45fke2a-v1_0-181106.pdf
Datasheet revision
Revision 1.0, 11/06/2018
Added

Specifications belong to CCI and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.

Report an error in these specs

Upload a newer datasheet revision