CCI

HPA45R-BU6AB-K

Six-foot (1.8 m), multiband, six-port panel, 45° azimuth beamwidth, 698–896 and 1695–2400 MHz.

Antenna · Panel Verified from manufacturer datasheet
Manufacturer PDF Product page

Ordering variant of HPA45R-BU6A documented in its datasheet (DS-HPA45RBU6A-V1.0-180108): identical electrical specs; AB = 3x BSA-RET400 Type 17 internal RET actuators with MBK-01 bracket. Front-to-back ratio published as a minimum ('> N dB') in the datasheet; recorded as the plain number. Ordering parts HPA45R-BU6AA-K, HPA45R-BU6AB-K.

SPEC.COVCoverage6 band rows
Band, MHz Ports GainHorizontal BWVertical BWElectrical tilt PIM, dBc Power / port
698–806MHz 1-2 15.6dBiavg 15.3 51° 12.1° 2–12° -150dBc 500W
824–896MHz 1-2 16.6dBiavg 16.1 47° 10.5° 2–12° -150dBc 500W
1695–1880MHz 3-6 18.9dBiavg 18 44° 5.3° 2–10° -150dBc 300W
1850–1990MHz 3-6 19.3dBiavg 18.7 43° 4.9° 2–10° -150dBc 300W
1920–2180MHz 3-6 19.7dBiavg 19 42° 4.6° 2–10° -150dBc 300W
2300–2400MHz 3-6 20dBiavg 19.2 43° 4.1° 2–10° -150dBc 300W

Remote Electrical Tilt (RET), AISG 2.0

SPEC.ELEElectrical
Polarization
±45°
VSWR
1.5: 1
PIM, 3rd order
By band, see Coverage
Max input power
By band, see Coverage
Impedance
50Ω
Isolation
>25 dB (698–896 MHz, 1695–2400 MHz)
SPEC.MECMechanical
Dimensions
1828 x 391 x 208mm
Weight
29kgexcludes mounting
Wind load
Front 1136 N, side 680 N at 100 mph
Max wind speed
241 km/h (150 mph)
Connectors
6x 4.3-10 female
Port count
6
Mounting
MBK-01 mounting bracket included
SPEC.PRTPorts6 total
  • Ports 1-2 698–896MHz
  • Ports 3-6 1695–2400MHz
1+2−3+4−5+6−
Illustrative port layout — drawn from the published 6 ports and ±45° polarization. The arrangement is schematic; the exact positions are in the manufacturer PDF.
  • Ports 1–2698–896MHz
  • Ports 3–61695–2400MHz
SPEC.PATRadiation patterns6 bands
0°90°180°270°HBW 51°
Horizontal — 698–806MHz
0°90°180°270°VBW 12.1°tilt 2–12°, shown at 7°
Vertical — 698–806MHz

Illustrative patterns — the main lobe is drawn on a 0 to −30 dB scale so its −3 dB width matches the published beamwidth. The back lobe, where shown, sits at the published front-to-back ratio. Sidelobes are not drawn. The exact plots are in the manufacturer PDF.

CALC.EIRPUse this gainEIRP / ERP

Pick a band. The gain comes from the table above. Add your transmit power and feed loss to get EIRP.

EIRP — Turn on JavaScript, or use the calculator link.

EIRP = TX power − loss + gain (dBi). ERP = EIRP − 2.15 dB. Open the full EIRP calculator →

SOURCESource and corrections
Source
Manufacturer datasheet PDF, read 2026-11-12: https://cciproducts.com/DsPdf/ds-hpa45rbu6a-v1_0-180108.pdf
Datasheet revision
Revision 1.0, 01/08/2018
Added

Specifications belong to CCI and can change without notice. The manufacturer’s current datasheet is the authority; check it before you sign a report. Everything on this page is public data — the same datasheet anyone can find with a Google search. Nothing here is proprietary.

Report an error in these specs

Upload a newer datasheet revision