The math, without the spreadsheet.
Fourteen calculators for the questions RF engineers ask every week: dBm to watts, EIRP, path loss, VSWR, exposure limits. Type a number, get the answer and the formula behind it.
Free, no login, and nothing leaves your browser.
Convert between decibels and a power ratio. Use the amplitude toggle for voltages or field strengths.
Formula, worked example and notes →
Edit any field — the others recompute. dBm is referenced to 1 mW; dBW is referenced to 1 W (offset 30 dB).
Formula, worked example and notes →
A half-wave dipole has 2.15 dBi of gain over an isotropic radiator. dBd subtracts that reference.
Formula, worked example and notes →
FCC and ITU spec sheets typically use dBi. Older broadcast antenna catalogs often quote dBd.
The three numbers every line sweep produces. Edit any one — the others recompute.
Formula, worked example and notes →
Free-space wavelength at the speed of light. Useful for first-cut antenna sizing, near/far-field bounds, and Fresnel-zone math.
Formula, worked example and notes →
Below this distance you are in the radiating near-field — power-density math from FSPL or Friis breaks down. Plug in the antenna's largest physical dimension.
Formula, worked example and notes →
Tx power minus cable losses plus antenna gain. EIRP references isotropic; ERP references a half-wave dipole (subtract 2.15 dB).
Formula, worked example and notes →
Explained in EIRP vs ERP: What That 2.15 dB Actually Means →
Path loss for a clear line-of-sight link with no obstructions, ground reflection, or atmospheric absorption. Floor of every link budget.
Formula, worked example and notes →
Explained in Demystifying Free-Space Path Loss →
End-to-end signal level at the receiver. Useful for quick microwave / backhaul / 5G NR LOS sanity checks.
Formula, worked example and notes →
Far-field power density on boresight. Compare against the MPE limit for your population (lookup below).
Formula, worked example and notes →
Solve for distance that satisfies S ≤ MPE. Worst-case (free-space) bound; real exclusion zones are typically smaller.
Formula, worked example and notes →
Maximum Permissible Exposure power-density limits per FCC OET-65, Table 1. Type any cellular frequency to see the limit for that band.
Formula, worked example and notes →
Explained in OET-65 in 60 Seconds: How the FCC MPE Limits Actually Work →
| FREQUENCY RANGE | GENERAL PUBLIC | OCCUPATIONAL |
|---|---|---|
| 3 – 30 MHz | 180/f² mW/cm² | 900/f² mW/cm² |
| 30 – 300 MHz | 0.2 mW/cm² | 1.0 mW/cm² |
| 300 – 1500 MHz | f / 1500 mW/cm² | f / 300 mW/cm² |
| 1.5 – 100 GHz | 1.0 mW/cm² | 5.0 mW/cm² |
Source: FCC OET Bulletin 65, Edition 97-01, Table 1 (limits for Maximum Permissible Exposure). Below 3 MHz the limits are E-/H-field driven and not shown here.
Power-density limits at any frequency under both regulators. ISED column uses the exact power-density reference levels of Health Canada Safety Code 6 (2015), Tables 5 and 6.
Formula, worked example and notes →
Explained in FCC vs ISED Canada: Cross-Border RF Safety in Practice →
| POPULATION | FCC OET-65 (USA) | ISED · Safety Code 6 (Canada) | Δ (Stricter) |
|---|---|---|---|
| General Public / Uncontrolled | — | — | — |
| Occupational / Controlled | — | — | — |
| Time-Averaging (GP / Occ) | 30 / 6 min | 6 / 6 min | — |
For a cross-border program, the time-averaging difference alone can flip a borderline site. Between 300 MHz and 6 GHz, Safety Code 6's public limit is 0.02619·f0.6834 W/m² (f in MHz), averaged over 6 minutes; the FCC's is f/1500 mW/cm² from 300 to 1500 MHz, then 1.0 mW/cm², averaged over 30 minutes. Always reference the source regulatory text for compliance work.
Total cable + connector loss for a Tx feed. Pick a common cable type to autofill attenuation per 100 ft at the typical band centers; or enter your own.
Formula, worked example and notes →
Manufacturer datasheets are the authoritative source. Values shown are typical at 25 °C and tend to increase with temperature and age.